6
Fig. 1 — 62X Model Number Information (cont)
a62-767
Supply Fan
2
350 mm, BI
3 450 mm Low, BI
4
450 mm High, BI
5
500 mm Low, BI
6
500 mm High, BI
7
560 mm, BI
D
10 in., BI
E
11 in., BI
F
12 in., BI
G
14 in., BI
H
16 in., BI
J
18 in., BI
K
20 in., BI
M
22 in., BI
N
25 in., BI
Power Exhaust Fan Motor Options
- None
A 1 HP ODP with VFD
B 1 1/2 HP ODP with VFD
C 2 HP ODP with VFD
D 3 HP ODP with VFD
E 5 HP ODP with VFD
F 7 1/2 HP ODP with VFD
G 10 HP ODP with VFD
H 15 HP ODP with VFD
J 1 HP TEFC with VFD
K 1 1/2 HP TEFC with VFD
M 2 HP TEFC with VFD
N 3 HP TEFC with VFD
P 5 HP TEFC with VFD
Q 7 1/2 HP TEFC with VFD
R 10 HP TEFC with VFD
S 15 HP TEFC with VFD
T – ECM*
U – Dual ECM*
SEE PREVIOUS PAGE
FOR REMAINDER
OF MODEL NUMBER
NOMENCLATURE
H
Revision H Controls
A 208-3-60 VCC Lead Circuit Standard Efficiency
C 208-3-60 VCC Lead Circuit High Efficiency
E 230-3-60 VCC Lead Circuit Standard Efficiency
G 230-3-60 VCC Lead Circuit High Efficiency
J 460-3-60 VCC Lead Circuit Standard Efficiency
M 460-3-60 VCC Lead Circuit High Efficiency
P 575-3-60 VCC Lead Circuit Standard Efficiency
R 575-3-60 VCC Lead Circuit High Efficiency
Design Series
None 2 in. MERV 8
A None 4 in. MERV 8
B None 4 in. MERV 11
C None 4 in. MERV 13
D Smoke detector 2 in. MERV 8
E Smoke detector 4 in. MERV 8
F Smoke detector 4 in. MERV 11
G Smoke detector 4 in. MERV 13
Control Filter MERV
Option Thickness
Control Options and Filters
B
HC07 - E62X
E
H
KBR
AR
E
Voltage Options, Compressor and Condenser Fans
Voltage Compressor Condenser Efficiency
P
12 in., AF
Q
14 in., AF
R
16 in., AF
S
18 in., AF
T
20 in., AF
U
22 in., AF
V
25 in., AF
Exhaust Fan
-
None
2
350 mm, BI
3 450 mm Low, BI
4
450 mm High, BI
5
500 mm Low, BI
6
500 mm High, BI
7
560 mm, BI
D
10 in., BI
E
11 in., BI
F
12 in., BI
G
14 in., BI
H
16 in., BI
J
18 in., BI
K
20 in., BI
M
22 in., BI
N
25 in., BI
P
12 in., AF
Q
14 in., AF
R
16 in., AF
S
18 in., AF
T
20 in., AF
U
22 in., AF
V
25 in., AF
a62-768
Factory Installed Options
Refer to tables on page 6 for
available option codes
LEGEND
AF Airfoil
BI Backward Inclined
ECM Electronically Commutated Motor
N/A Not Applicable
ODP Open Drip Proof
TEFC Totally Enclosed Fan Cooled
VCC Variable Capacity Compressor
VFD Variable Frequency Drive
*ECM supply and exhaust fan motors are not avail-
able in 575 V. See physical data tables for ECM
motor availability per cabinet size.