5. Installation site selection
Selection of best suitable location is must before product installation, this will result best performance
INDOOR UNIT
OUTDOOR UNIT
Please maintain min 1000mm from all sides for
easy servicing of machine parts.
Space between two ducted units should be more
than 1.2meter to avoid short cycling or lack of air
circulation.
(Above drawing is for reference only).
Space between two units should be at least
1000mm.
Please maintain min 450mm from all sides for
easy servicing of machine parts.
Consider dimensions drawing of unit and keep
clear path for both air suction and air discharge.
Consider dimensions drawing of unit and keep
clear path for rejected heat exhaustion.
Unit must not be on direct sunlight path and
must be away from source of heat / steam /
Vapors.
Recommended to use sunroof to safeguard unit
from heavy rainwater or strong wind strokes.
Suitable drainage provision and slope.
Provision for drain water as it must not cause any
trouble.
Select best location as per room area for even
distribution of cooled air.
Unit must be 3meters away from TV antennas etc.
Corded remote must be installed at user
accessible position. Cord must not be tried to
overextend from its original length.
Keep away from direct pollution or smoke.
Site or location must be sufficient for doing
convenient piping, electrical work, ducting,
servicing & maintenance.
Site or location must be sufficient for doing
convenient piping, electrical work, servicing and
maintenance.
Mounting location must be able to bear load
more than 4times the weight of Indoor unit.
There should be no plantation or pet animal in
front of hot air discharge.
*Recommended unit space