Table.1
9.4 Indoor Unit Operation by “Corded Remote”
1. POWER ON/OFF
Switch On “Main Power supply”, Press button to turn ON/OFF the Air Conditioner.
When turn ON, it will operate according to the setting shown on the Display unit.
2. “Mode Selection” changes are done by Button to Fan and Cool mode.
▪ FAN: The System will operate as the fan only .In this mode, the temperature setting and Sleep
Function will not operate.
▪ COOL: The System will operate as the cooling unit.
The Compressor will
• Increase Capacity if Troom > Tset.
• Decrease capacity if Troom < Tset.
• Stop if Troom < Tset-1.5.
However, the compressor is subjected to 6-minutes delay protection each time it stops.
▪ DRY: The System will operate as the Humidifier.
*Note: In Dry mode, Fan Button will not operate.
3. “Temperature Settings” (Increase and Decrease) are done by “ ” & “ ” Button.
Press Temp “ ”down or Temp up “ ” button to set the temperature in a range of 18 to 32
deg C.