Do you have a question about the Carrier High Wall Duct Free Split System 38MVC and is the answer not in the manual?
Model | 38MVC |
---|---|
Refrigerant | R-410A |
Inverter Technology | Yes |
Operating Voltage | 208/230V |
Indoor Unit Dimensions (HxWxD, in) | Varies by model |
Outdoor Unit Dimensions (HxWxD, in) | Varies by model |
Wi-Fi Compatible | Yes (with optional interface) |
Provides an overview of the service manual's content and purpose.
Details the components and meaning of the unit's serial number.
Details standard features for indoor unit installation and operation.
Describes optional accessories for outdoor units like low ambient kit.
Details pipe sizes and lengths for cooling-only units.
Details pipe sizes and lengths for heat pump units.
Shows the location and measurements of service valves on outdoor units.
Details minimum clearance requirements around the indoor unit.
Details minimum clearance requirements around the outdoor unit.
Diagram showing the refrigeration flow for cooling operation.
Diagram showing the refrigeration flow for heat pump operation.
Covers basic rules for refrigerant line sizing and installation.
Specific considerations for refrigerant line lengths exceeding 25 ft.
Detailed steps for using the deep vacuum method to evacuate the system.
Detailed steps for using the triple evacuation method to evacuate the system.
Explains the compressor's 3-minute delay function for protection.
Details compressor overcurrent protection mechanisms and parameters.
Discusses the wireless remote control and manual button interface.
Details the operation when only the fan is active.
Explains the cooling mode, including sub-modes like Sleep and Turbo.
Describes how the compressor and outdoor fan cycle in cooling mode.
Explains how the indoor fan operates in auto mode for cooling.
Emergency operation when the remote control is lost or batteries expire.
Operation for diagnostic purposes, forcing the unit into cooling mode.
A flowchart to guide the troubleshooting process based on symptoms.
Lists the necessary tools for diagnosing unit issues.
Lists the contents and corresponding numbers within the appendix.
Control board input/output values for 38MVC009/012 units.
Control board input/output values for 40MVC009/012 units.
Input/output values for control boards of specific heat pump models.
Control board input/output values for 38MVC012-3 units.
Control board input/output values for 40MVC012-3 units.
Input/output values for control boards of specific 3-phase heat pump models.
Control board input/output values for 38MVC018-3 units.
Control board input/output values for 40MVC018-3 units.
Input/output values for the indoor unit display board.
Diagnostic guide for 9K & 12K indoor units.
Diagnostic guide for 18K & 24K indoor units.