PG96MSA: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
21
Table 9 – Air Filter Selection and Duct Sizing - In. (mm)
Air Filter Located in Filter Cabinet
A150580
NOTE: Local codes may require a drain pan and condensate trap when
a condensing furnace is installed over a finished ceiling.
Fig. 26 – Working Platform for Attic Installation
A150581
NOTE: Local codes may require a drain pan and condensate trap when
a condensing furnace is installed over a finished ceiling.
Fig. 27 – Suspended Furnace Installation
Leveling Legs (If Desired)
In upflow position with side return inlet(s), leveling legs may be used.
See Fig. 28. Install field-supplied, 5/16 x 1-1/2 in. (8 x 38 mm) (max)
corrosion-resistant machine bolts, washers and nuts.
NOTE: Bottom closure must be used when leveling legs are used. It
may be necessary to remove and reinstall bottom closure panel to install
leveling legs. To remove bottom closure panel, see Fig. 24.
To install leveling legs:
1. Position furnace on its back. Locate and drill a hole in each bottom
corner of furnace.
2. For each leg, install nut on bolt and then install bolt with nut in
hole. (Install flat washer if desired.)
3. Install another nut on other side of furnace base. (Install flat washer
if desired.)
4. Adjust outside nut to provide desired height, and tighten inside nut
to secure arrangement.
5. Reinstall bottom closure panel if removed.
A89014
Fig. 28 – Leveling Legs
FURNACE
CASING
WIDTH
FILTER SIZE
FILTER TYPE
*
*. Filters with a side return-air may have a different filter size. Measure the
filter to obtain the correct size.
SIDE
RETURN
BOTTOM
RETURN
14-3/16 (360)
16 x 25 x 3/4
(406 x 635 x 19)
14 x 25 x 3/4
(356 x 635 x 19)
Washable
17-1/2 (445)
(1) 16 x 25 x 3/4
(406 x 635 x 19)
(1) 16 x 25 x 3/4
(406 x 635 x 19)
Washable
21 (533)
(1) 16 x 25 x 3/4
(406 x 635 x 19)
(1) 20 x 25 x 3/4
(508 x 635 x 19)
Washable
24-1/2 (622)
(1) 16 x 25 x 3/4
(406 x 635 x 19)
(1) 24 x 25 x 3/4
(610 x 635 x 19)
Washable
FILTER
CABINET
HEIGHT - IN
(MM)
FILTER SIZE - IN (MM)
*
*. Filters with a side return-air may have a different filter size. Measure the
filter to obtain the correct size.
FILTER
TYPE
†. Recommended to maintain air filter face velocity. See Product Data for part
number.
16 (406)
(1) 16 x 25 x 3/4 (406 x 635 x 19) or
(1) 16 x 25 x 4-5/16 (406 x 635 x 110)
Washable or
Media
20 (508)
(1) 20 x 25 x 3/4* (508 x 635 x 19) or
(1) 20 x 25 x 4-5/16 (508 x 635 x 110)
Washable or
Media*
24 (610)
(1) 24 x 25 x 3/4* (610 x 635 x 19) or
(1) 24 x 25 x 4-5/16 (610 x 635 x 110)
Washable or
Media*
2-IN.
(51 mm)
ROLLOUT PROTECTION REQUIRED
Install 12” x 22” (305x559 mm) sheet metal in front of burner compartment
area. The sheet metal MUST extend underneath the furnace casing by 1-in.
(25 mm) with the door removed. The bottom closure panel may be used for
flame roll-out protection when bottom of furnace is used for return air connection.
30 IN. (762 mm)
MIN. WORK AREA
COMBUSTION - AIR PIPE
(SEE VENTING SECTION)
1
3
/
4
1
3
/
4
1
3/
4
1
3/
4
5/
16
5
/
16
5/
16
5/
16
(44mm)
(8mm)
(44mm)
(8mm)
(8mm)
(8mm)
(44mm)
(44mm)