Dip Switch
Dip switch denition
Dip Switch SWl\
SWl ON OFF Default
Swl Slave wired controller Master wired controller OFF
Swl-2 Room temperature display on Room temperature display o OFF
Swl-3 Room temperature collected from indoor unit Room temperature collected from
controller
OFF
Swl-4 System remains o after power loss Auto restart after power loss OFF
Swl-5 Old protocol (models develioed before Ayg, 2013 New protocol OFF
Swl-6 Backlight always on Backlight 15 second auto time out OFF
Swl-7 Reserved Reserved OFF
Dip Switch SWl 2
SW2 ON OFF Default
Swl Slave wired controller Master wired controller OFF
Sw2-1 Mode Lock Normal Normal
No button conrmation tone.
(Tone will still be audible when
command is sent by wireless remote.)
Tone on OFF
Sw2-3 Reserved Reserved OFF
Sw2-4 Reserved Reserved OFF
Initialization
When the mini-split system is powered on, 88.8 will ash between the Room Temperature display and the Set Tem-
perature display, until communication is established with the indoor unit.
Audible Alert
Press to power ON or power OFF the control. A tone will be heard with every button press or when a command
is received by a remote control. If a conicting command is received, then the tone will beep 3 times.
English