5-3-2. RS-232 (Serial Communication) Function
F26
Function Set Device ID
Display Meaning
F26. 00
Device ID 00
Setting range
(00 ~ 99)
F26. 99 Device ID 99
Note 1. This function enables to use the unique indicator ID in the command mode.
F27
Function Set Parity Bit – RS232C & PRT
Display Meaning
F27. 0
Data bit 8, stop bit 1, parity bit: none
F27. 1 Data bit 7, stop bit 1, parity bit: even number
F27. 2 Data bit 7, stop bit 1, parity bit: odd number
Setting range
(0 ~ 3)
F27. 3 Data bit 7, stop bit 2, parity bit: odd number
Note 1. F26 and F27 apply commonly to 2 serial communications (RS23C and PRT).
Serial Communication COM1 Function
F28
Function Set COM1 Baud Rate
Display Meaning
F28. 0 600 bps
F28. 1 1200 bps
F28. 2 2400 bps
F28. 3 4800 bps
F28. 4
9600 bps
F28. 5 19200 bps
F28. 6 38400 bps
F28. 7 57600 bps
Setting range
(0 ~ 8)
F28. 8 115200 bps
F29
Function Set COM1 - Usage
Display Meaning
F29 0
Connect to a printer
Setting range
(0 ~ 1)
F29 1 Connect to a computer or auxiliary display
* If F29: 0 and F33 : 0, "ERR-Set" is displayed with no print.
F30
Function Set COM1 - Output Format
Display Meaning
F30 0
22 bytes for CAS
F30 1 10 bytes for CAS
Setting range
(0 ~ 2)
F30 2 18 bytes for AND