EasyManua.ls Logo

CAS RW-10L - Error Message Troubleshooting; Troubleshooting Common Errors (01-09)

CAS RW-10L
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Road Weigher
▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩
- 17 -
10. Error message and Trouble Shooting
Err 01
Reason
The weight is too unstable to initialize the scale
Trouble shooting
Lay the scale on a plat place and turn on the power.
Err 02
Reason
Load cell connection failure or error in A/D conversion part.
Trouble shooting
Check the load cell connector to see if the polarity of signal is reversed.
Err 06
Reason
Error in printer connection
Trouble shooting
Check with printer connector
If there is no problem with printer connector, please request
A/S to head office.
Err 08
Reason
The ZERO key or TARE key is adjusted not to be operated under the unstable
condition.
Trouble shooting
Press ZERO or Tare key in stable condition
Err 09
Reason
Current weight deviates from zero range.
Trouble shooting
Press zero key within 10% of the maximum capacity.
Err 13
Reason
Tare weight exceeds the maximum capacity of the scale.
Trouble shooting
Set the tare to be smaller than maximum capacity.
Otherwise the maximum capacity is reset to be larger than the tare to be
set in the calibration menu, and reset the calibration using weight.

Related product manuals