  • S
    Stacey JonesAug 18, 2025
    How to fix 'current weight deviates from zero range' error on CAS CI-2001B?
    • S
      Steven EdwardsAug 18, 2025
      If your CAS Accessories scale shows that the current weight deviates from the zero range, you can press the ZERO key. Note that this only works if the deviation is within 10% of the maximum capacity.
  • T
    Tiffany MiddletonAug 21, 2025
    How to calibrate CAS CI-2001B if zero range deviates?
    • L
      Lori BarkerAug 21, 2025
      If the zero range deviates from the set range on your CAS Accessories scale, first confirm that there is nothing on the weighing platform. If the platform is empty, perform a calibration in CAL mode.
  • A
    Andrew Smith MDAug 27, 2025
    What to do if the tare weight exceeds the maximum capacity on CAS CI-2001B?
    • T
      Teresa VasquezAug 27, 2025
      If the tare weight exceeds the maximum capacity of your CAS Accessories scale, set the tare to be smaller than the maximum capacity.
  • K
    Kathy KingAug 30, 2025
    How do I resolve load cell connection issues in CAS CI-2001B Accessories?
    • N
      nwalkerAug 30, 2025
      To resolve load cell connection issues in your CAS Accessories device, check the load cell connector to ensure the signal polarity is correct. If the load cell is damaged, it should be replaced.
  • R
    ryan67Sep 2, 2025
    What should I do if the weight on the CAS Accessories platform is too heavy?
    • N
      Nicholas SimsSep 2, 2025
      If the weight on the platform of your CAS Accessories scale is too heavy to be measured, do not load items that exceed the maximum tolerance.
  • T
    Terry SmithSep 5, 2025
    What if load cell output is too low or high during SPAN calibration on CAS Accessories?
    • C
      Carla RoseSep 5, 2025
      If the load cell output is too low or too high during SPAN calibration on your CAS Accessories scale, proceed with calibration again using less resolution.
  • S
    savagechristopherSep 8, 2025
    What to check if load cell output is too high at ZERO calibration on CAS Accessories?
    • M
      Marissa FisherSep 8, 2025
      If the load cell output is too high at ZERO calibration on your CAS Accessories scale, check if the platform is empty. Then, proceed with calibration again after checking in A/D TEST mode.
  • M
    Mary BeckSep 12, 2025
    How to troubleshoot printer connection errors on CAS CI-2001B?
    • H
      holmespamelaSep 12, 2025
      To troubleshoot printer connection errors with your CAS Accessories device, check the printer connector.
  • C
    christianedwardsNov 14, 2025
    Why does my CAS CI-2001B scale show an error in calibration mode?
    • C
      Cathy GreenNov 14, 2025
      Errors during calibration of your CAS Accessories scale can stem from several reasons. One common cause is setting the resolution beyond the limit of 1/10,000; try lowering the resolution. Another reason might be that the weight used for span calibration is less than 10% of the scale's maximum capacity. In this case, set the weight for span calibration in CAL 3 to exceed 10% of the maximum capacity. Conversely, if the weight for span calibration surpasses 100% of the scale's maximum capacity, adjust it to be within the limit. If the load cell output is either too low or too high during SPAN calibration, attempt the calibration again with less resolution. If the load cell output is too high at ZERO calibration, ensure the platform is empty and repeat the calibration after checking in A/D TE...
  • E
    Elizabeth BennettNov 23, 2025
    What to do if my CAS CI-2001B scale shows an error in weighing mode?
    • B
      bonillabrittneyNov 23, 2025
      If your CAS Accessories scale displays an error during weighing, several factors could be responsible. It could be due to a failure in the load cell connection or an error in the A/D conversion. Check the load cell connector, paying attention to the signal polarity. Another potential cause is an error in the printer connection, so inspect the printer connector. If the current weight deviates from the zero range, press the ZERO key, provided the deviation is within 10% of the maximum capacity. Also ensure that the tare weight does not exceed the scale's maximum capacity. If the zero range deviates from the set range, ensure the weighing platform is empty and perform calibration in CAL mode. Finally, make sure that the weight on the platform does not exceed the maximum tolerance. If the load...

Summary

Precautions and Features

Technical Specifications

Analog Part Specifications

Details of analog components, voltage, sensitivity, and resolution.

Digital Part Specifications

Specifications for digital display, size, and power consumption.

Front Panel Operations (CI-2001 A)

Key Part Functions

Details the function of each key on the front panel.

Front Panel Operations (CI-2001 B)

Key Part Functions (CI-2001 B)

Details the function of each key on the front panel.

Installation and Load Cell Connection

Test Mode Operations

How to Enter Test Mode

Instructions on how to activate the Test Mode.

Calibration Mode Operations

How to Enter Calibration Mode

Instructions on how to activate the Calibration Mode.

Set Mode Configuration

How to Enter Set Mode

Instructions on how to activate the Set Mode.

Serial Interface Communication

Error Messages and Troubleshooting

Errors in Weighing Mode

Lists common errors encountered during weighing operations.

Err 02: Load Cell or A;D Conversion Error

Load cell connection failure or A/D conversion error.

Err 06: Printer Connection Error

Error related to printer connection.

Err 08: ZERO;TARE Key Unstable Condition

ZERO or TARE key adjustment issue under unstable condition.

Err 09: Zero Range Deviation

Current weight deviates from zero range.

Err 10: Tare Weight Exceeds Capacity

Tare weight exceeds the maximum capacity.

Err 13: Zero Range Deviation from Set Range

Zero range deviates from the set range.

Over: Platform Weight Exceeds Tolerance

Platform weight exceeds measurement tolerance.

Errors in Calibration Mode

Lists common errors encountered during calibration.

Err 21: Resolution Limit Exceeded

Resolution limit (1/10,000) exceeded.

Err 22: Low Span Calibration Weight

Span calibration weight is too low (under 10% capacity).

Err 23: High Span Calibration Weight

Span calibration weight is too high (over 100% capacity).

Err 24: Small Load Cell Output (Span)

Load cell output too small at SPAN calibration.

Err 25: Large Load Cell Output (Span)

Load cell output too large at SPAN calibration.

Err 26: Large Load Cell Output (Zero)

Load cell output too large at ZERO calibration.

CAS CI-2001B Specifications

General IconGeneral
BrandCAS
ModelCI-2001B
CategoryAccessories
LanguageEnglish