Road Weigher
▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩
- 15 -
Select the primary base unit
0
Primary unit is kg
F01
1
Primary unit is lb
Serial port usage
0
Not used
F02
1
Connection with Serial printer
Automatic Zero Tracking
0
Not used.
F03
1
~
9
1 : 0.5 digit
~
9 : 4.5 digit
Auto zero tracking will automatic-
ally bring the displayed back to
"0" when there are small
deviations
Digital Filter
F04
1
~
9
1 : Less Vibration
~
9 : Much Vibration
Adjust the set value according
to the condition.
Select the wight Back-Up mode
0
Weight Back-up is off
F07
1
Weight Back-up is on