Road Weigher
▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩▩
- 21 -
9. Error message and Trouble Shooting
Err 02
▣ Reason
Load cell connection failure or error in A/D conversion part.
☞ Trouble shooting
Check the load cell connector to see if the polarity of signal is reversed.
Err 06
▣ Reason
Error in printer connection
☞ Trouble shooting
Check with printer connector
If there is no problem with printer connector, please request
A/S to head office.
Err 08
▣ Reason
Error in units
☞ Trouble shooting
Check units(kg/lb).It should be same
Err 13
▣ Reason
Tare weight exceeds the maximum capacity of the scale.
☞ Trouble shooting
Set the tare to be smaller than maximum capacity.
Otherwise the maximum capacity is reset to be larger than the tare to be
set in the calibration menu, and reset the calibration using weight.
Over
▣ Reason
The weight on platform is too heavy to be measured.
☞ Trouble shooting
Do not load cell item exceeds the maximum tolerance.
If the load cell is damaged, the load cell should be replaced.