17
E550 - E550 CR - E550 PM - E550 PM CR Automatic Single-Side Edgebander Rel. 1.1.1
1.6 NOISE EMISSION
In accordance with standards ISO 3744/94 – ISO 7960/95 Annex F.
When running idle without dust extraction:
AVG 78.6 [dB (A)7]OpE 77.7 [dB (A)] OpU 77.5 [dB (A)]
When machining with dust extraction:
AVG 79.7 [dB (A)] OpE 79.2 [dB (A)] OpU 79.8 [dB (A)]
Key:
AVG Average acoustic pressure level
OpE Acoustic pressure level at input operator position
OpU Acoustic pressure level at exit operator position
1.7 DUST EMISSION
The operations that can generate dust emissions are ush trimming and end trimming.
When the machine is connected to an efcient suction system that ensures an airow speed of at least 20
mm/sec, dust emission values are lower than the required limit of 2 mg/m3.
1.8 OPERATOR POSITION
The operator position indicated in Fig. 1.8.1 allows all operating controls and emergency devices to be
reached, ensuring maximum convenience and practicality of use.
CAUTION! Area of automatic movement of panels being edged
The work area indicated in Fig. 1.8.1 shows the space that must be left free around the machine for
operations of cleaning, maintenance and normal use.
1.9 EMISSIONE FUMI
E550 E550 PM E550 CR E550 PM CR
A
MAX workpiece length
B
2000 mm
C
1000 mm + MAX width of workpiece to be edged
RED AREA – prohibited
YELLOW AREA – work position: CAUTION! Area of automatic movement
of panels being edged
GREEN AREA – work zone