8 215204 Rev. 1
I
10
Cycle Clamp functions
With no load, cycle each Clamp function
several times.
Check for operation in accordance with
ITA (ISO) standards.
Clamp and lift a maximum load. Sideshift
left and right. Check for equal arm
movement and adequate sideshift speed.
If necessary, adjust relief valve cartridges
(see Section 5.3-4).
Check for leaks at fittings, valve, manifold
and cylinders.
AUXILIARY VALVE
FUNCTIONS
NSTALLATION
WARNING: Make sure all personnel are
clear of the Clamp during testing.
B
D
C
A
GA0005.ill
NON-SIDESHIFTING CLAMPS
A Release Arms
B Clamp Arms
C
(not used)
D
(not used)
SIDESHIFTING CLAMPS
A Sideshift Left
B Sideshift Right
C Release Arms
D Clamp Arms
SIDESHIFTING CLAMPS WITH
SOLENOID VALVE
A Sideshift Left
A Release Arms
(press knob button)
B Sideshift Right
B Clamp Arms
(press knob button)
B
A
A
B
CL0022.ill
CL0023.ill
CL0274.ill
A
B
A
A
B
C
D
C
A
Tilt Forward
Hoist Up
Tilt Back
Hoist Down
11
Adjust relief valves
For over-pressure protection, the relief
valves for both CLAMP and SIDESHIFT
functions should be adjusted to match the
truck hydraulic flow rate. See Section 5.3-4
for adjustment procedure.