Loading...
2 215204 Rev. 1
I
NSTALLATION
2.1 Truck System
Requirements
E-Series Clamps will provide maximum operating capabil-
ity when the following requirements are met.
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of
the original truck manufacturer and may be
less than that shown on the attachment
nameplate. Consult the truck nameplate.
GA0082.ill
Clamp
Sideshift
Right
Tilt
Forward
Hoist Up
Auxiliary Valve Functions
Check for compliance with ITA (ISO) standards:
Tilt
Back
Hoist Down
Release
Sideshift
Left
GA0080.ill
Carriage
Clean carriage bars and inspect for
damaged notches
GA0028.ill
Carriage Mount Dimension (A) ITA (ISO)
Minimum Maximum
Class II 14.96 in. (380.0 mm) 15.00 in. (381.0 mm)
Class III 18.68 in. (474.5 mm) 18.74 in. (476.0 mm)
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
Min.
Recommended Max.
20E, 30E, 33E, 5 GPM 7.5 GPM 10 GPM
40E, 45E (19 L/min.) (28 L/min.) (38 L/min.)
Cascade E-Series Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid is
not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
Flow less than recommended will result in reduced system
performance.
Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
A