34 215204 Rev. 1
ERVICE
S
5.3-3 Valve Service
IMPORTANT: Service the Valve in a clean work area.
E-Series Clamps use three different types of Valve assem-
blies: non-sideshifting, sideshifting, and sideshifting with
regeneration. Service procedures are the same for all.
1 Remove the Valve from the Clamp as described in
Section 5.3-1.
2 Remove the cartridges from the Valve.
3 Remove the remaining plugs and fittings.
4 Remove the O-rings and back-up rings from the car-
tridges.
5 Clean all parts with cleaning solvent or kerosene.
6 For reassembly, reverse the above
procedures with the following exceptions:
Replace the O-rings
and back-up rings on
the cartridges as
shown below.
Lubricate the car-
tridges, fittings and
plugs with petroleum
jelly prior to installation.
Tighten cartridges to 30 ft.-lbs. (40 Nm).
CAUTION: Assure that the cartridges are installed in the
correct port location in the Valve body. Refer to the part
number stamped on the hex end of the cartridge.
CL0362.ill
CL0341.ill
CL0342.ill
Check Valve Cartridge (209847)
O-rings (2)
Back-up ring (1)
O-rings (4)
Back-up rings (6)
CL0338.ill
CL0339.ill
CL0634.ill
Check Valve Cartridge – Regen. Circuit (210261)
Directional Valve Cartridge – Regen. Circuit (210263)
Cross-Over Relief Cartridge (214405–Clamp)
(215876–Sideshift)
(212971–Regeneration)
O-rings (4)
Back-up rings (6)
Flow Divider Cartridge (210266)
Back-up rings (6)
Back-up rings (2)
O-rings (2)
O-rings (4)
A
B
C
B
C
E
E
Non-Sideshifting Valve
D