44 215204 Rev. 1
PECIFICATIONS
S
GA0091.ill
6.1 Specifications
6.1-1 Hydraulics
6.1-3 Truck Carriage
GA0090.ill
Tilt
Back
GA0082.ill
Clamp
Sideshift
Right
Tilt
Forward
Hoist Up
Hoist Down
Release
Sideshift
Left
GA0028.ill
A
Carriage Mount Dimension (A) ITA (ISO)
Minimum Maximum
Class II 14.94 in. (380.0 mm) 15.00 in. (381.0 mm)
Class III 18.68 in. (474.5 mm) 18.74 in. (476.0 mm)
6.1-2 Auxiliary Valve Functions
Check for compliance
with ITA (ISO) standards:
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
➀
Min.
➁
Recommended Max.
➂
20E, 30E, 33E 5 GPM 7.5 GPM 10 GPM
40E, 45E (19 L/min.) (28 L/min.) (38 L/min.)
➀ Cascade E-Series Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
➁ Flow less than recommended will result in reduced system
performance.
➂ Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
Hoses and Fittings
All supply hoses must be at least No. 6 minimum.
All fittings must have an orifice size of 9/32 in. (7 mm)
minimum.