EasyManua.ls Logo

Cascade E-Series - Specifications; Hydraulics; Auxiliary Valve Functions; Truck Carriage

Default Icon
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 215204 Rev. 1
PECIFICATIONS
S
GA0091.ill
6.1 Specifications
6.1-1 Hydraulics
6.1-3 Truck Carriage
GA0090.ill
Tilt
Back
GA0082.ill
Clamp
Sideshift
Right
Tilt
Forward
Hoist Up
Hoist Down
Release
Sideshift
Left
GA0028.ill
A
Carriage Mount Dimension (A) ITA (ISO)
Minimum Maximum
Class II 14.94 in. (380.0 mm) 15.00 in. (381.0 mm)
Class III 18.68 in. (474.5 mm) 18.74 in. (476.0 mm)
6.1-2 Auxiliary Valve Functions
Check for compliance
with ITA (ISO) standards:
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
Min.
Recommended Max.
20E, 30E, 33E 5 GPM 7.5 GPM 10 GPM
40E, 45E (19 L/min.) (28 L/min.) (38 L/min.)
Cascade E-Series Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
Flow less than recommended will result in reduced system
performance.
Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
Hoses and Fittings
All supply hoses must be at least No. 6 minimum.
All fittings must have an orifice size of 9/32 in. (7 mm)
minimum.