215204 Rev. 1 43
ERVICE
S
RC0204.ill
2
3
4
Coil
Solenoid Valve
Assembly
5.6 Solenoid Valve
5.6-1 Coil Service
1 Remove the cover from the valve assembly.
2 Disconnect the wires and diode from the coil terminals.
3 Loosen the end cover capscrews. Remove the end
cover and coil.
4 Install the new coil and end cover. Assure that the
terminals are positioned correctly.
5 For reassembly, reverse the above procedures except
as follows:
• Refer to the electrical schematic in Section 4.5 for
correct wire and diode installation.
5.6-2 Valve Service
• Check the plunger within the valve body for freedom of
movement. If jammed or damaged, replace the
solenoid valve as a complete assembly.