E-48
Precautions for Use
• Even if the battery in the DT-X400 is already fully charged, charging will begin when 
you set the DT-X400 in the Ethernet cradle. It may take several minutes for the fully 
charged status to be indicated.
• In high- or low-temperature environments, charging may be restricted to protect the 
battery pack. At such temperatures, the level of battery charge may not reach 100% 
even when the charging status LED is green and charging is completed.
• Water or other moisture on the power contacts could cause sparking or an electric 
shock, and soiled contacts could block the connection and impair charging 
functionality. To ensure safety, clean the power contacts by wiping them off  with a 
dry cloth or cotton bud after you disconnect the AC adapter.
• When disconnecting the AC adapter from the mains power outlet and DT-X400, do 
so by gripping the connector and not by pulling on the cord.
Ethernet Cradle (HA-S62IO) Specifications
1.  LAN specifi cations
  Communications method  : IEEE 802.3-compliant
  Media type  : 10base-T/100base-TX auto switched
2.  Charging specifi cations
  Charging method  : Constant-voltage constant-current charging
  Charging time  : Approx. 4 hours
3.  AC adapter specifi cations
  Standard  : AD-S50400A
  Input  : 100-240V AC, 50/60 Hz, 0.7A
  Output  : 5V DC, 4A
4.  Dimensions, weight
  Dimensions  : Approx. 102(W) × 140(D) × 131(H) mm
  Weight  : Approx. 380g
5.  Operating environment
  Operating temperature  : 0°C to 40°C
  Operating humidity  : 10-90% RH (condensation-free)