Regardless of whether the flow detector is installed in the vertical or horizontal position,
the arrow engraved on the detector must point along the water circulation direction.
arrow
WATER
CIRCULATION
VERTICAL INSTALLATION HORIZONTAL INSTALLATION
WATER
CIRCULATION
Installing the Pool Terre
®
The
Pool-terre device is necessary to carry electrostatic charges contained in the
water to earth.
When it is connected to an earthing terminal, this device eliminates leakage currents
and reduces oxidation and reduction phenomena responsible for corrosion.
• Install the 50/50/1/2" Tee on the discharge pipe on the downstream side of the
heating or electrolysis equipment.
• Connect the Pool-terre to the equipotential pipe, giving priority to a direct
connection to the earthing rod and using a green and yellow cable with
appropriate cross-section (not less than 16mm²).
Discharge
Earth
Earthing cable
minimum 16mm²
POOL TERRE
Use Teflon for the
seal