Display
The state of the system is displayed by lights:
Light Color Status Meaning
POWER ON (n)
Yellow Off
On
Box not powered
Normal operation
CIRCULATION (q)
Green Off
On
No circulation.
Circulation (Pump in operation).
PRODUCTION (r)
Green
Off
On
Out of production
In production
The production indicator
The ammeter
t is used to check the production level of the unit.
Production check
The measurement dial is divided into three parts (less than 4 amperes, 4 to 6 amperes,
more than 6 amperes), representing the production level.
Part Production Action
0 to 4 A Low Increase production using s, check the salt
content or clean the cell.
4 to 6 A Normal
6 to 10 A Excessive
overproduction
Reduce production using
s
Excess salt - Check the salt content
The production level must be kept within the 4 to 6 A range at all times.
Production fault
In case of overproduction (current exceeding 6 A). This fault usually occurs if there is
too much salt in the pool.
The control box is equipped with a rated circuit breaker
u that cuts off production in
the case of overproduction, so that the cell cannot be damaged by an overcurrent.
This fault is cleared by waiting for a few minutes to allow the unit to cool, and then
resetting
u and reducing production using switch s until the needle returns to the
central part of the indicator. If the unit overproduces because there is too much salt,
replace some of the water in the pool until the salt content is acceptable.
Checking the salt content
The salt content in the pool must not drop below 2g/l when the water temperature is
25°C. It is recommended that the salt content should be kept between 2.5g/l and
4.5g/l to protect the electrolysis cell. The water conductivity varies with the
temperature. The salt content should be kept above 3.5 g if LIMPIDO is to operate in
water below 18°C.