NOTICE TECHNIQUE V2 LIMPIDO-PRO
CCEI
page 11
Electrical connection
• The electrical connection of the LIMPIDO has been very much simplified:
The power supply cable is supplied with a standard plug. The installer may remove
this plug to make a fixed connection if he wishes.
The cell and flow detector connections are made on professional type connectors
and are differentiated from each other.
• Make sure that the electrical installation on the inlet side of the box is capable of
guaranteeing the safety of persons and the equipment. In particular, we
recommend that a high sensitivity 30 mA differential should be installed at the
starting point of the pool electrical circuit.
IMPORTANT: Never work on a live cabinet; switch off its power supply either at the
cutoff device provided in the technical room, or on the main switchboard for the
home if it is accessible.
STARTUP
Check on the salt content
Use the salt tester supplied with the instrument.
Take off the protective cap at the end of the tester and then briefly press the ON/OFF
button in order to start the instrument. Dip the end of the tester in the water sample to
be analyzed. Do not immerse the appliance beyond the striated part.
When the display is steady, read the value directly on the screen or press the HOLD
key, which will prevent the displayed value from changing when you take the tester
out of the analyzed sample.
The value is expressed in ppm (parts per million) or mg/l (milligram per liter). The
measurement range varies from 1 mg/l to 9,990 mg/l . Since the display only shows 3
figures, the tester displays an
x10 symbol immediately after the value read when this
value exceeds 999 mg/l. Thus 450
x10 means 4,500 mg/l or 4.5g/l.
Câble secteur à
brancher sur
une prise 230V
Prise 230V
Asservie
( Pompe
Doseuse )
Cellule
Détecteur de ciculation
Mains cable to be
connected to a
230 V connector
230V socket
Slaved (Dosage
pump)
Circulation detector
Cell