NOTICE TECHNIQUE V2 LIMPIDO-PRO
CCEI
page 3
CHARACTERISTICS
General
Dimensions – box alone - (w x h x d)
Weight
Power supply voltage
single-phase
Protection index
Insulation
320x420x200
8kg
230V / 50Hz
IP-65-8
Class II
Electrolysis
Chlorine production
Pool volume
Cell cleaning
Consumed power
Minimum salt content
Max. pressure in the cell
Max. flow in the cell
Electrodes
48g/h
60 to 160m
3
Polarity inversion
250 W
2 g/l to 25°C
3 bars
22m
3
/h
Solid titanium plates
Ruthenium coating
Accessories supplied
Flow detector (x1)
with equipment:
- 63/63/25 Tee (x1)
- 25/¾" (x1) nipple
- 20/27 seal (x1)
POOL-TERRE electrode (x1)
with equipment:
- 50mm 1/2" Tee (x1)
Union fitting (x2)
Technical instructions (x1)
Salt tester (x1)
PRESENTATION
How the unit works
The LIMPIDO 100 is a sterilising system which functions by electrolysis of salt water. The
Electrolytic process separates the salt present (NaCl) into sodium (Na) and chlorine
(Cl), which immediately dissolves in the water to make hypochlorous acid (HClO).
This is a powerful disinfectant which kills any bacteria and algae before changing
back into salt. The electrolyser only produces chlorine when the flowmeter detects
that water is circulating in the cell.
The electrolysis unit only produces chlorine during filtration periods determined by the
programming clock. During these filtration periods, the production time is composed
of cycles made up of two periods (Normal and Inverse) that alternate the polarity of
the electrodes. This polarity inversion avoids scaling of the electrodes. The duration of
each production cycle is about 2h00 and it is broken down as follows: