NOTICE TECHNIQUE V2 LIMPIDO-PRO
CCEI
page 12
Affichage du taux de sel.
Unité: x10 ppm ou g/l
100 mg/l = 100 ppm = 0,1g/l
350
x10 m g /l = 3,5 g /l
O N /OFF : P re s s e r s u r ce tte
touche pour m ettre en
m arche et arrêter le tes teur
.
Ne pas
immerger au-
delà de la z one
striée
HOLD: Presser sur cette
touche pour m ém oriser la
mesure.
IMPORTANT: Do not use the electrolysis unit when the salt concentration is less than
2g/l.
Adjusting the production level
The chlorine quantity produced by LIMPIDO is proportional to the time during which it
is in operation. Therefore, production will be adjusted by increasing or reducing the
programmed number of hours and holding the position of the indicator needle t
between 4A and 6A using a switch s.
It is recommended that the production indicator should be monitored frequently
during the first week in service, and the production level should be corrected as soon
as the needle goes outside the 4 to 6 ampere range:
0 to 4A range Increase production
6 to 10A range Reduce production
The chlorine quantity necessary to maintain the water quality in a pool depends on
many parameters:
• Water acidity (pH)
• Water hardness (TH)
• Water temperature
• Sunshine (UV radiation)
• The stabilizer content (isocyanuric acid)
• Volume of the pool
In particular, if a stabilizer is used, the content of free chlorine needs to be equal to
2mg/l (2ppm), while 0.4mg/l is necessary to treat a pool without a stabilizer.
Similarly, an increase in the pH (lack of acid) quickly reduces the quantity of active
chlorine contained in the water. Thus, the percentage of active chlorine is divided by
4 when the pH increases from 7.2 to 8.2.
ON/OFF: Press this
button to switch the
tester On and Off
Salt content display
Unit x10 ppm or g/l
100 mg/l = 100 ppm = 0.1 g/l
350 x10 mg/l = 3.5 g/l
HOLD: Press this button
to memorize the
measurement