18 INSTALLATION MANUAL
On-Board Protection
24VDC: 2.5A Fuseless Protection
12VDC: 1A Fuseless Protection
5VDC: 1A Fuseless Protection
AC Protection: 5A Fuse
Battery Reversal Protection: 7A Fuse
Fuse Failure Indication: Event Generation and LED Display on ALL supplies
Battery Backup
Battery Capacity: Two 12VDC, 7Ah
Low Battery @: 20.5VDC
Low Battery Restore @: 23.4VDC
Low Battery Cut-Off @: 16.8VDC
Outputs
Lock Outputs: 2 Outputs: 350mA @12/24VDC
Relays: 2 Form «C» Relays: 5A 30VDC Resistive (Expandable to 16 with CA-A460)
Programmable Outputs: 6 Open Collector 25mA Sink
• Distributed Architecture (100% off-line operation) • Local Anti-passback
• Dynamic Memory Adjustment • Operates with all Centaur Software Applications
• E-Bus for Plug and Play expansion modules • Ethernet or Network Ready
• On-Line Upgradable Firmware • Supports elevator control
• Multiple Reader Technology • RS-232 and RS-485 support