CT-V900 CONTROLLER 17
SYSTEM SPECIFICATIONS
RECOMMENDED WIRING
CT-V900 CONTROLLER SPECIFICATIONS
System Resources
Doors: 2 (expandable to 8)
Cards: 10,920 (expandable)
Schedules: 512 (expandable)
Buffered Events: 2048 (expandable)
Operating Temperature: 5°C to 55°C (41°F to 133°F)
System Autonomy: Full Distributed Architecture (100% Off-line Operation)
Firmware: Online Upgradeable
Cabinet (Custom Printable): H: 39cm (15.5»), W: 33cm (13»), D: 10cm (4»)
Elevator Control (Centaur 3.0 only)
Controlled Elevators: 2
Floors per Elevator: 64
Schedules per Floor per Elevator: Yes
Floor Groups: 128
Inputs
Readers: 2 Wiegand or Track 2 Magnetic Swipe Card Readers
Keypads: 2 Wiegand and/or BCD Keypads
Multi-Purpose Inputs: 8 using N.C. or 16 using ATZ with 2R/3R
Controller Tamper: Normally Closed (N.C.) contact
Communication
Ports: 2 (expandable)
RS-232 Support: Network (Lite Edition) or Modem Connection
Controller Network: RS-485 @ 9.6K baud/19.2K baud, Ethernet 10 BASE T,
Fiber-Optic Interface Support and RS-232
Expansion Bus (E-Bus): RS-485, Plug and Play
Max. Distance (E-Bus): 1220m (4000ft.)
Power Supply
AC Power: 24VAC, 75VA
Frequency: 50Hz/60Hz
Max. Current: 2.5A
AC Loss Indicator: Yes
www.cdvgroup.com