Check the condition of the electrode, nozzle, nozzle holder and swirl ring of the torch.
Replace if they show signs of wear.
Check for the presence of the three phases of supply voltage on terminals TP1, TP2, TP3 of
power board (20).
Check the presence of the gas at the inlet fitting (B) and that the pressure and flow rate in the
intake conduit meet the specification values (see Instruction Manual).
Make sure the pressure regulator (E) and pressure gauge (F) are working properly.
Make sure that there are no partial blocks in the gas lines of the power source, especially in
the section involving the solenoid valve EL2 (37).
Replace solenoid valve EL2 (37).
Replace the control (9) and/or power board (20).