CEBORA S.p.A. 24
5.3
- Fuse board (18) code 5.602.148.
5.3.1 - Topographical drawing.
5.3.2 - Connector and fuse table.
Conn. Terminals Fuse Value Function
J1 1 – 2 F1 0.5 A 24 Vac power supply output for start button circuit on the torch.
J2 1 – 2 F5 2 A 27 Vac power supply output for solenoid valves (37) and pilot arc relay.
J3 2 – 3 F2 1 A 16 Vac setting board (19) power supply output.
J3 3 – 4 F3 1 A 16 Vac setting board (19) power supply output.
J4 A – B - - service transformer (18) power supply input.
J5 A – B F4 2 A service transformer (18) power supply, 230 Vac power supply output
for fan (45).
5.4
- Relay board (27) code 5.602.161.
5.4.1 - Topographical drawing.
5.4.2 - Connector table.
Connector Terminals Function
- J1 nozzle voltage input.
- J2 nozzle voltage output.
- J3 NU.
J4 1(+) – 2(-) filter capacitor connection on relay board (27).
J5 1 - 2 27 Vac input for pilot arc relay command on relay board (27).
3.302.167 25/06/04