FI002K0018v1100UK – THS/21 Instruction manual for installation, use and maintenance
ORIGINAL INSTRUCTIONS 1
Industrial Metal Detectors
and Integrated Systems with Conveyor Belt
THS/21E - THS/21
Instruction manual
for installation, use
and maintenance
Document Date Hardware Software
FI002K0018v1100UK 2012-03-29 HV5.xx THSV5401 – ALMV5400
Read this manual carefully before installing, operating or carrying out maintenance on the device. Keep the manual in a
safe place for future reference and in perfect condition. This manual must accompany the device described herein in the
case of change of ownership and until the device is decommissioned.

Table of Contents

Questions and Answers

  • T
    Tonya WalkerJul 25, 2025
    Why is my Ceia THS/FBB giving false alarms?
    • S
      Scott CurryJul 25, 2025
      False alarms on your Ceia Metal Detector may be due to electrical or mechanical disturbances. Try performing the Environmental Compatibility Check procedure with normal operating settings. If the source isn't identified, the issue might be a malfunction. In this case, disconnect all devices connected to the metal detector. If possible, connect it to a different power supply and earth source, ensuring the environment is free from interference. If the problem continues, it may require professional assistance.
  • I
    Isaiah MckenzieAug 1, 2025
    What to do if my Ceia THS/FBB Metal Detector doesn't detect test samples?
    • R
      Ryan VillaAug 1, 2025
      If your Ceia Metal Detector isn't alarming when using test samples, it could be due to a few reasons. First, ensure the correct product is selected. If not, repeat the Autolearn procedure to automatically set the sensitivity. Also, the sample might not have the right diameter for the current product. Set the default product and create a new one. Check that the samples are detected, if necessary by increasing the sensitivity value. If they are detected, samples with a bigger diameter must be used for the current product.
  • J
    Justin RiveraAug 18, 2025
    How to troubleshoot a Ceia THS/FBB with a control panel display that is not on?
    • C
      chavezjosephAug 18, 2025
      If the control panel display on your Ceia Metal Detector is not on, check the connections between the SCD card and the ALM card. Disconnect all the devices connected, switch off the system and switch it on again after a few minutes, if self-resetting protective devices have been activated. If the Metal Detector can expel metal masses, verify the RCU card is correctly connected to the ALM card. Otherwise, inspect the state of fuse F10 (and F11/F12 for Conveyor Control System) and ensure the power supply voltage is within the permitted range.
  • L
    Lori MejiaNov 5, 2025
    How to fix a Ceia Metal Detector conveyor belt that won't start?
    • L
      lewisjimmyNov 5, 2025
      If the conveyor belt in your Ceia Metal Detector system isn't starting, there are several things to check: * If the belt running indicator is off, ensure the KT parameter isn't zero and is correctly set. Also, inspect the inverter connections inside the power supply unit. * If the belt running indicator is on, verify the inverter is correctly configured for the connected motor (check NMV, NMF, NMC parameters) and inspect the motor connections. For non-integrated systems, ensure the connected motor is compatible with the inverter output characteristics. * If the belt running indicator is flashing, check that the FOLLOWING CONVEYOR input is active or, if it is not used, set FC=OFF. * If the belt running indicator is only on when the key is pressed, check the inverter connections wit...
  • J
    Jamie BrownNov 11, 2025
    What to do if the ejector on my Ceia THS/FBB isn't working after an alarm?
    • C
      cookwesleyNov 11, 2025
      If the ejector on your Ceia Metal Detector isn't activating after an alarm and there's no fault message, here's what you can check: * If the ejector isn't working and there's no ejection confirmation sensor, check the ejector connections. For non-integrated systems, ensure the electrical characteristics are compatible with those provided by the power supply card. If used, check the activation of the EJECT RELAY and its fuse. * If the ejector is working (checked in I/O status) and ejection confirmation check is correctly activated, and you're in synchronized ejection mode, verify the synchronization photocell is activated correctly and operating. If an encoder is installed, check that the speed measured is correct. If no encoder is installed, check that the KE parameter is equal to 0. ...

Summary

SAFETY INSTRUCTIONS - WARNINGS

Device Users and Training Requirements

Details required instruction levels and training for different user roles throughout the device lifecycle.

Safety Warnings and Precautions

Covers general, installation, use, and maintenance warnings to ensure safe operation and prevent incidents.

DESCRIPTION

INSTALLATION

General Installation Requirements and Clearances

Specifies general installation requirements and minimum clearances needed around the equipment.

Pneumatic and Electrical Installation

Covers procedures for pneumatic and electrical connections, including input/output descriptions.

Configuration and System Setup

Guides on device configuration, motor setup, transit speed, and encoder settings.

USE OF THE DEVICE

Programming Access and Operation

Guides users on how to access and perform programming functions on the Metal Detector.

MAINTENANCE

Troubleshooting Common Issues

Provides guidance on diagnosing and resolving common faults and error messages.

Ceia THS/FBB Specifications

General IconGeneral
BrandCeia
ModelTHS/FBB
CategoryMetal Detector
LanguageEnglish