FI002K0018v1100UK – THS/21 Instruction manual for installation, use and maintenance
ORIGINAL INSTRUCTIONS 1
Industrial Metal Detectors
and Integrated Systems with Conveyor Belt
THS/21E - THS/21
Instruction manual
for installation, use
and maintenance
Document Date Hardware Software
FI002K0018v1100UK 2012-03-29 HV5.xx THSV5401 – ALMV5400
Read this manual carefully before installing, operating or carrying out maintenance on the device. Keep the manual in a
safe place for future reference and in perfect condition. This manual must accompany the device described herein in the
case of change of ownership and until the device is decommissioned.

Table of Contents

Questions and Answers

  • R
    Robert Myers DDSJul 25, 2025
    Why is my Ceia THS/G21 Metal Detector giving false alarms?
    • A
      angelalambertJul 26, 2025
      False alarms on your Ceia Metal Detector may be due to electrical or mechanical disturbances. Try performing the Environmental Compatibility Check procedure with normal operating settings. If the source isn't identified, the issue might be a malfunction. In this case, disconnect all devices connected to the metal detector. If possible, connect it to a different power supply and earth source, ensuring the environment is free from interference. If the problem continues, it may require professional assistance.
  • J
    javiergillespieJul 31, 2025
    What to do if my Ceia Metal Detector doesn't detect test samples?
    • N
      nicholasmolinaJul 31, 2025
      If your Ceia Metal Detector isn't alarming when using test samples, it could be due to a few reasons. First, ensure the correct product is selected. If not, repeat the Autolearn procedure to automatically set the sensitivity. Also, the sample might not have the right diameter for the current product. Set the default product and create a new one. Check that the samples are detected, if necessary by increasing the sensitivity value. If they are detected, samples with a bigger diameter must be used for the current product.
  • J
    Justin PalmerAug 18, 2025
    How to troubleshoot a Ceia THS/G21 with a control panel display that is not on?
    • P
      paynetinaAug 18, 2025
      If the control panel display on your Ceia Metal Detector is not on, check the connections between the SCD card and the ALM card. Disconnect all the devices connected, switch off the system and switch it on again after a few minutes, if self-resetting protective devices have been activated. If the Metal Detector can expel metal masses, verify the RCU card is correctly connected to the ALM card. Otherwise, inspect the state of fuse F10 (and F11/F12 for Conveyor Control System) and ensure the power supply voltage is within the permitted range.
  • S
    sdiazNov 6, 2025
    How to fix a Ceia THS/G21 conveyor belt that won't start?
    • G
      Gloria JohnsonNov 6, 2025
      If the conveyor belt in your Ceia Metal Detector system isn't starting, there are several things to check: * If the belt running indicator is off, ensure the KT parameter isn't zero and is correctly set. Also, inspect the inverter connections inside the power supply unit. * If the belt running indicator is on, verify the inverter is correctly configured for the connected motor (check NMV, NMF, NMC parameters) and inspect the motor connections. For non-integrated systems, ensure the connected motor is compatible with the inverter output characteristics. * If the belt running indicator is flashing, check that the FOLLOWING CONVEYOR input is active or, if it is not used, set FC=OFF. * If the belt running indicator is only on when the key is pressed, check the inverter connections wit...
  • D
    Darrell PayneNov 11, 2025
    What to do if the ejector on my Ceia THS/G21 isn't working after an alarm?
    • R
      Ryan FletcherNov 11, 2025
      If the ejector on your Ceia Metal Detector isn't activating after an alarm and there's no fault message, here's what you can check: * If the ejector isn't working and there's no ejection confirmation sensor, check the ejector connections. For non-integrated systems, ensure the electrical characteristics are compatible with those provided by the power supply card. If used, check the activation of the EJECT RELAY and its fuse. * If the ejector is working (checked in I/O status) and ejection confirmation check is correctly activated, and you're in synchronized ejection mode, verify the synchronization photocell is activated correctly and operating. If an encoder is installed, check that the speed measured is correct. If no encoder is installed, check that the KE parameter is equal to 0. ...

Summary

1 Safety Instructions - Warnings

2 Description

2.3 Integrated Systems with Conveyor Belt

Information on integrated systems with conveyor belts and their configurations.

2.8 Technical Characteristics

Lists technical specifications for Metal Detectors and integrated systems.

2.9 Safety Devices

Details safety features like IP protection, cable glands, and self-diagnosis.

3 Installation

3.5 Electrical Installation

Instructions for electrical installation, including cable connections and I/O interfaces.

3.7 Connections to Other Devices

Details connections for external devices like push-buttons and sensors.

3.8 Configuration

Steps for configuring the Metal Detector for installation and product type.

4 Use of the Device

4.4 Switching on the Metal Detector

Steps for checking safety features and switching on the device.

4.5 Use of the Device

Covers checking sensitivity, starting/stopping the belt, and adjusting speed.

4.8 Sensitivity Check with Reference Sample

Procedures for performing sensitivity checks with reference samples.

4.9 Settings for CFR21 Standards

Settings required for compliance with CFR21 standards.

5 Maintenance

5.1 Periodic Maintenance

Lists periodic maintenance operations and their suggested frequencies.

5.2 Periodic Maintenance Procedures

Provides detailed procedures for periodic maintenance tasks.

5.3 Troubleshooting

Tables for diagnosing and resolving common faults and issues.

5.4 Extraordinary Maintenance Procedures

Procedures for extraordinary maintenance like changing fuses or cards.

5.5 Compatibility Check Procedures

Procedures for checking general, electrical, and belt contamination compatibility.

Ceia THS/G21 Specifications

General IconGeneral
Operating Temperature-10°C to +55°C
Protection RatingIP65
ApplicationsFood industry, pharmaceutical industry
ConstructionStainless steel
User InterfaceLCD display
Data LoggingYes
ConnectivityUSB
DimensionsVaries depending on configuration
Power Supply115/230 VAC, 50/60 Hz
Battery LifeNot applicable
Operating FrequencyVariable according to application
SensitivityAdjustable; optimized for specific products
WeightVaries depending on configuration