www.cellarcool.com | Page 59
Magnum Series
MAINTENANCE SCHEDULE
Monthly
1. Check for debris surrounding condensing unit (i.e. leaves, branches, trash, etc.); remove all
obstructions
2. Check for unusual noise or vibration
3. Check the drain line to see if it is above the waterline (if draining into a vessel)
Every Six
Weeks
Using the supplied drain line brush, clean the P-trap and drop a pan tab into the drip tray (see
the following page for more details).
Quarterly
1. Use a vacuum with brush attachment to clean the evaporator coil; be careful not to crush
coil ns when cleaning
2. Ensure the condensing unit is free of debris and dust
3. Have a certied HVAC technician service the condensing unit and clean the condenser coil
Annually
1. Inspect for corrosion
2. Check wiring connections and integrity of cords
3. Pour a 50/50 bleach solution into the drain line every spring
NOTE: For ducted systems, CellarCool recommends lters with a mean eciency reporting value (MERV) of 4 or
better. Filters are not included with the unit.