Trouble-
shooting
guide
page 30
Symptom
Cause
Action
Gate does not
autoclose.
Infrared beam(s) (if
fitted) is(are) faulty
Check that the auto-
close override facility
is not being operated
Check that the GREEN
LEDs adjacent the ‘Safe
CLS’ and ‘Safe OPN’
inputs are ON when the
infrared beams are clear
Check that beam is
correctly aligned. It
should be possible to hear
the relay within the
‘receiver’ side of the
infrared beam ‘click’ as
the beam is broken and
cleared
Ensure that nobody is
mistakenly pressing and
holding down the gate-
release pushbutton on,
either the remote, or
intercom for too long
when activating the unit.
Refer section Autoclose
Override
Gate starts closing
but stops and re-
opens.
Check the GREEN ‘Safe
CLS’ LED on controller. It
must remain ON if beam
is clear
Consult your installer if
there is a problem
Disconnect the VECTOR2
from the gate by remov-
ing the pin from the gate
bracket. Check that the
operator runs correctly
when not loaded by the
gate. Consult your
installer if there is a
problem
Intermittent operation
of infrared beam if
fitted
Anti-crushing device
is set too sensitively
Operator drives
too far and does
not stop in the
correct open and
closed positions.
Origin system not
functioning correctly
Origin position has
been shifted
Check that the cables
from the VECTOR2
actuator are terminated
correctly and making
good contact. Consult
your installer should there
be a problem

Other manuals for Centurion VECTOR2

Related product manuals