Chapter 5
After-use Care and Maintenance
Edition 1 – December 2019 SAFETY FIRST 129
MSA G1 Electronic Breathing Apparatus
Storage of the MSA G1 Electronic BA
Do not drop the cylinder or bump the valve knob.
Apply the following guidelines for safekeeping and storage.
Do not store the BA or spare cylinders within or near an area where the BA can or
might be exposed to any substances that will or might attack any part of it, causing
it to not perform as designed and approved.
Prior to storing the BA in a seat bracket ensure there is no interference between the
BA and the seat. Ensure the BA and cylinder can be removed easily without
damaging the components.
Do not store the BA with an empty cylinder or a cylinder with air pressure below
250 bar. Always install a fully-charged cylinder so that the BA is ready for use.
Complete the inspection, cleaning and disinfecting procedures as prescribed.
Always store the BA clean and dry.
Ensure the full facemask head harness adjustment straps are fully extended.
Do not store any loose objects in the full facemask bag.
Always store the full facemask in bag.