34
Gate operator setup examples
The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access
trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
SETTING RESIDENTIAL
COMMERCIAL/GENERAL
ACCESS
COMMERCIAL INDUSTRIAL
Quick Close switch
setting
Normally set to OFF. Normal gate
close (timer or control).
Normally set to OFF. Normal gate
close (timer or control).
Normally set to OFF. Normal gate
close (timer or control).
Set to ON, so that gate closes
immediately after vehicle passes
CLOSE EYES/Interrupt loop.
Anti-Tail switch setting
Normally set to OFF. CLOSE
EYES/Interrupt loop reverses a
closing gate.
Normally set to OFF. CLOSE
EYES/Interrupt loop reverses a
closing gate.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
Bipart Delay switch
setting
For DUAL-GATE site, set to ON for
gate that delays upon opening.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
Aux Relay Out Open
Limit Switch
Typically not required. Use with SAMS (Sequence Access
Management System).
1. Use with SAMS (Sequence
Access Management
System).
2. Connect “Gate Open
indicator (e.g. light).
1. Use with SAMS (Sequence
Access Management
System).
2. Connect “Gate Open
indicator (e.g. light).
Aux Relay Out Close
Limit Switch
Typically not required. Typically not required. Connect “Gate Close/Secure
indicator (e.g. light).
Connect “Gate Close/Secure
indicator (e.g. light).
Aux Relay Out Gate
Motion
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Aux Relay Out Pre-
Motion Delay
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Aux Relay Out Tamper
(Slide Gates Only)
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Cycle Quantity Feedback
Use during servicing only to
determine operator cycles.
Use during servicing only to
determine operator cycles.
Use during servicing only to
determine operator cycles.
Use during servicing only to
determine operator cycles.
Fire Dept Open Input
Typically not required. Connect emergency access
system (Knox box switch, SOS
system, etc.).
Typically not required. Typically not required.
Heater Accessory
(Models HTRNB and
HTR460)
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
SETTINGS