11
Install Without Adjustable Rails
Check the national and local building codes before installation.
NOTE: The rails will have to be removed for retro-fit installations.
1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter
heavy walled pipe. Posts should be parallel and square to the gate.
2. Locate electrical conduit, as required, prior to pouring concrete.
3. Remove the rails from the sides of the operator.
4. Secure operator to posts using four 3" (7.6 cm) U-bolts and
hardware.
5. Fill any empty holes on the side of the operator with the extra bolts
from the rails.
INSTALLATION