EasyManua.ls Logo

Chamberlain Swing GATE - Page 47

Chamberlain Swing GATE
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 of 53 Doc 6001242 (01-20273) Rev C
SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a
vehicle. If the gate is already moving, or if the gate is not fully opened or
closed, this input has no effect.
INSIDE/OUTSIDE INTERRUPT LOOP DETECTOR (TB16)
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "ON"
Gate fully open or closed: activation prevents the gate from moving.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, an opening gate closes and a closing gate resumes its course.
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "OFF"
Gate fully open or closed: activation prevents the gate from moving.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, the gate resumes its course.
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "ON"
Gate fully open or closed: activation prevents the gate from closing.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts a closing gate. When the
Interrupt Loop clears, an opening gate closes and a closing gate resumes its
course.
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "OFF"
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens a closing gate and starts
the Reclose Timer if timer is "ON".
OUTSIDE
INTERRUPT LOOP with ATG "OFF"
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens the closing gate and starts
the Reclose Timer if timer is "ON".
OUTSIDE
INTERRUPT LOOP with ATG "ON"
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.
INTERRUPT BAR INPUTS (TB11)
INTERRUPT BAR Activation fully opens a closing gate and stops an opening gate. If RETRY
is ON, the gate waits 30 seconds, then tries to resume. The gate will re-try
twice before faulting out. If the Interrupt Bar remains active for more than 30
seconds, the gate will not retry.