Configuring Appliances
Quantum Force 19000 and 29000 Appliances Getting Started Guide|43
To monitor the RAID status of the storage devices using SNMP:
Set up SNMP traps to send information about the RAID.
Use this OID: 1.3.6.1.4.1.2620.1.6.7.7
For more information about how to configure the SNMP settings on the appliance, see the
Gaia Administration Guide
for your version.
To hot swap a storage device:
Important - Make sure that there is at least one fully synchronized storage device in
the appliance.
1. When the appliance is up, remove the failed storage device.
2. Wait 15 seconds.
The appliance recognizes that you removed a storage device.
3. Insert a new storage device.
If necessary, you can reboot the appliance with one storage device and install the new
storage device later.
The appliance automatically adds the new storage device to the RAID configuration.