R410A50Hz Universal Outdoor Series Technical Manual Floor & Ceiling Indoor Unit
105
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6.9 CUA-48HR1
MODEL
CUA-48HR1
HEATING
OUTDOOR CONDITIONS
Indoor
Conditions
24ºC D
18ºC W
12ºC D
11ºC W
C D
C W
C D
C W
C D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W
15ºC
Capacity kW
26.21
20.95
17.45
15.71
14.83
13.09
12.22
Input kW.
8.47
6.79
5.62
5.37
5.09
4.81
4.54
118ºC
Capacity kW
24.58
19.68
16.4
14.76
13.93
12.29
11.51
Input kW.
7.96
6.31
5.42
5.04
4.79
4.53
4.25
20ºC
Capacity kW
22.8
18.22
15.4
13.66
12.91
11.38
10.63
Input kW.
7.39
5.91
5.41
4.68
4.45
4.19
3.95
22ºC
Capacity kW
20.92
16.76
13.97
12.57
11.87
10.47
9.77
Input kW.
6.78
5.43
4.53
4.31
4.09
3.87
3.64
27ºC
Capacity kW
18.21
14.55
12.14
10.92
10.32
9.1
8.48
Input kW.
5.91
4.73
3.95
3.76
3.57
3.36
3.17
6.10 CUA-60HR1
MODEL
CUA-60HR1
HEATING
OUTDOOR CONDITIONS
Indoor
Conditions
24ºC D
18ºC W
12ºC D
11ºC W
C D
C W
C D
C W
C D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W
15ºC
Capacity kW
30.36
24.29
20.24
18.21
17.2
15.18
14.12
Input kW.
10.34
8.27
6.91
6.55
6.22
5.88
5.51
18ºC
Capacity kW
28.52
22.81
19.01
19.11
16.16
14.26
13.3
Input kW.
9.73
7.77
6.46
6.15
5.84
5.51
5.16
20ºC
Capacity kW
26.4
21.12
17.6
15.84
14.96
13.2
12.32
Input kW.
9.02
7.21
6.08
5.72
5.39
5.11
4.78
22ºC
Capacity kW
24.23
19.43
16.2
14.58
13.76
12.14
11.33
Input kW.
8.29
6.61
5.53
5.24
4.96
4.67
4.41
27ºC
Capacity kW
21.12
16.9
14.09
12.67
11.98
10.58
9.87
Input kW.
7.19
5.78
4.82
4.57
4.34
4.09
3.86