Material System Cleanout
AIR CLEANOUT METHOD (OPTIONAL)
1) Place material pump in neutral.
2) Remove sealing tip and return wand to access port..
3) Open wand valve (F) and sealing hose valve (A).
4) Close tank outlet valve (D).
5) Increase (close) pressure valve (B) to maximum.
6) Connect air hose and open air cleanout valve.
7) Allow air to blow freely through sealing hose. (Turn wand valve (F), open and closed
several times during this phase, to aid in cleaning valve. Leave valve open).
8) Open tank outlet valve (D) momentarily, then close.
9) Decrease (open) pressure valve (B) and leave open.
10) Close sealing hose valve (A).
11) Shut air hose off at compressor, close air cleanout valve and disconnect hose.
12) Proceed with normal machine shut down.
FLUSHING NON-REHEATABLE MATERIALS
1) Pump the material tank as low as possible.
2) Add 5 to 10 gallons of recommended flushing solvent to tank.
3) Place the wand into access port and open wand valve.
4) Circulate the solvent approximately 5 to 10 minutes.
5) Pump the solvent through the wand into a container and dispose of it according to EPA
guidelines.
6) Add another 5 to 10 gallons of material and circulate for 5 minutes.
7) Pump this 5 to 10 gallons into empty containers and reuse it for the first purge next time
the unit is used.