- 26 -
Material System Cleanout
FLUSHING REHEATABLE MATERIALS (Solvent Tank Option)
To save material, proceed through the five steps of the Reverse Flow Cleanout Method and
then:
1) Remove wand from access port and place end into waste container.
2) Open sealing hose valve and wand valve.
3) Connect solvent tank hose to air cleanout connection and open solvent tank flow valve.
4) Open air cleanout valve and allow 4-5 gallons of solvent to flow into the plumbing sys-
tem.
5) As the solvent is filling the system, turn the material pump to the normal flow position by
rotating knob counterclockwise.
6) The solvent will flush the system and empty into the waste container.
7) Turn "off" the solvent tank flow valve and the air cleanout valve. Return the material
pump knob to the neutral position.
8) Remove the sealing hose from the hose holder and drain as much solvent from the
hose as possible (Non-heated hose models only).
9) Close sealing hose valve, wand valve and open pressure valve.
10) Reuse the solvent if possible or dispose of it according to EPA guidelines.