SERIAL COMMANDS
#@ nnnn <CR>
Purpose To configure the scanner.
Remarks nnnn – the four digits of command parameters.
For example, “9952” is to list the current Code ID settings.
“0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d”
Note: After configuring the scanner, you may send the serial command “#@9999” to
save the settings.
#@ - - - -<CR>
Purpose To halt the scanner.
Remarks
“0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d”
#@ . . . . <CR>
Purpose To resume operation.
Remarks
“0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d”
#@////<CR>
Purpose To respond with a beep.
Remarks
“0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d”
Appendix I
HOST SERIAL COMMANDS
S
erial Comman
d
L
ist Page 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab 1100 and is the answer not in the manual?

CipherLab 1100 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Pitch reading angle-70 - 70 °
Optical sensor resolution3648 pixels
Light levels (direct sunlight)5 - 95 lx
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, GS1-128 (UCC/EAN-128), MSI, Pharmacode, Plessey, Telepen, U.P.C.
2D (matrix & stacked) barcodes supported-
Connectivity technologyWired
Product colorGray
Housing materialPolyurethane
Input voltage5 V
Power consumption (standby)0.06 W
Power consumption (typical)0.19 W
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth145 mm
Width93 mm
Height74 mm
Weight165 g