13
IMPORTANT: If mineral build-up is severe, more than one cleaning may be necessary to dissolve remaining solids. If you
can see any remaining scaling, debris, or physical blockages through Cell, flush the cell well with a garden hose nozzle.
Repeat the cleaning process if needed. Note: Cleaning this cell is only necessary to remove an excessive build-up of
minerals on the plates. A light coating of minerals does not impede performance. Unnecessary cleaning will reduce
lifespan of the cell.
OPTION 2:
1) Unscrew Cell Cap (around the Cell cable) from the Cell Housing.
2) Slide Cell Plate Assembly away from the Cell Housing. DO NOT pull or hold the Cell Plate Assembly by its cable. Slide the
cleaning stick between titanium plates and connection brackets to loosen and dislodge any mineral buildup or scale.
Hose off debris with a strong garden-hose nozzle. There should be no solids bridging gaps or connection between plates.
3) Ensure that the O-Ring and its channel are clean and securely seated.
4) Reinstall Cell into Cell Housing, carefully aligning the Cell’s raised key into the Housing’s matching slot. Reattach Cell
Cap only hand-tight (do not use wrench).
5) Reinstall cell into PVC return line, and ensure Cell cable connection is clean and tight on all three terminals.
IMPORTANT: Other than the supplied cleaning tool, do not insert anything or use metal or other hard objects to clean
the cell, this will void the warranty.