Mounting the Access Point
Figure 2-8 Pivoting Mounting Kit Dimensions
Table 2-3 Materials for Mounting on Wall with Pivoting Mounting Kit
Materials Required for mounting AP on a vertical wall
with pivoting mounting kit
In Kit
Ground lug and screws (provided with access point) Yes
Pivoting mount kit and hardware Yes
(8) M6 x 12-mm Hex-head Bolts Yes
Adapter bracket for option horizontal mount Yes
Two stainless steel band clamps (adjustable 2"-5", 51 mm -
127 mm)
Yes
Two stainless steel band clamps (adjustable 5"-8", 127 mm -
203 mm)
Yes
Crimping tool for ground lug, Panduit CT-720 with CD-720-1
die (http://www.panduit.com)
No
Four wall mounting screws (6mm max) No
Four wall anchors (specified for all material) No
Drill bit for wall anchors No
Electric drill and standard screwdriver No
#6 AWG ground wire No
Shielded outdoor-rated Ethernet (CAT5e or better) cable No
Grounding block No
Grounding rod No