3-12
Cisco AS5350 and Cisco AS5400 Universal Gateway Software Configuration Guide
OL-3418-02 B0
Chapter3 Basic Configuration Using the Command-Line Interface
Configuring a Channelized T3 Trunk Card
Configure
Verify
To verify that your controller is up and running and no alarms have been reported:
Enter the show controller command and specify the controller type, slot, and port numbers:
AS5400# show controller t3 1/0
T3 1/0 is down.
Applique type is Channelized T3
Transmitter is sending remote alarm.
Receiver has loss of signal.
FEAC code received: No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Line
Data in current interval (330 seconds elapsed):
0 Line Code Violations, 0 P-bit Coding Violation
0 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
0 Unavailable Secs, 0 Line Errored Secs
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Total Data (last 24 hours)
Command Purpose
Step 1
AS5400> enable
Password: password
AS5400#
Enters enable mode. Enters the password. You are
in enable mode when the prompt changes to
AS5350# or AS5400#.
Step 2
AS5400# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
AS5400(config)#
Enters global configuration mode. You are in
global configuration mode when the prompt
changes to
AS5350(config)# or
AS5400(config)#.
Step 3
AS5400(config)# controller t3 1/0
AS5400(config-controller)#
Enters controller configuration mode to configure
your T3 controller for slot 1 port 0. Slot values
range from 1 to 7. Port number is always 0.
Step 4
AS5400(config-controller)# framing c-bit
Enters your telcos framing type: c-bit or m23.
Step 5
AS5400(config-controller)# clock source
line
Enters your clock source: internal or line.
Step 6
AS5400(config-controller)# cablelength 450
Enters your cablelength: values range from 0 to
450 feet.
Step 7
AS5400(config-controller)# t1 1-28
controller
or
AS5400(config-controller)# t1 1-10,15-20,23
controller
Configures your T1 controllers. Range is 1 to 28.
In this instance, all 28 T1s are configured at once.
or
Omits specified T1 controllers while provisioning
others. In this instance, T1 controllers 11-14, 21,
22, and 24-28 are unprovisioned.
Note This CLI command is backward
compatible only.
Step 8
AS5400(config-controller)# Ctrl-Z
AS5400#
Returns to enable mode.