EasyManuals Logo

Cisco ASR 9006 Overview And Reference Guide

Cisco ASR 9006
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #168 background imageLoading...
Page #168 background image
A-14
Cisco ASR 9000 Series Aggregation Services Router Overview and Reference Guide
OL-17501-09
Appendix A Technical Specifications
Table A-22 lists the power consumption specifications for the RSP card, RP card, FC card, line cards,
and fan tray.
Caution Be sure that the chassis configuration complies with the required power budgets. Failure to properly
verify the configuration may result in an unpredictable state if one of the power units fails.
Note The fan tray power consumption numbers reflect the power budget for a single fan tray.
Table A-22 Card and Fan Tray Power Consumption Specifications
Description Value
RSP Card
Power consumption 175 W at 77°F (25°C)
205 W at 104
°F (40°C)
235 W at 131
°F (55°C)
RSP-440 Card
Power consumption 285 W at 77°F (25°C)
350 W at 104
°F (40°C)
370 W at 131
°F (55°C)
RP Card
Power consumption 227 W at 77°F (25°C)
251 W at 104
°F (40°C)
259 W at 131
°F (55°C)
FC Card (ASR 9922)
Power consumption 135 W at 77°F (25°C)
147 W at 104
°F (40°C)
160 W at 131
°F (55°C)
FC Card (ASR 9912)
Power consumption 80 W at 77°F (25°C)
82 W at 104
°F (40°C)
88 W at 131
°F (55°C)
8-Port 10-Gigabit Ethernet 2:1 Oversubscribed Line Card
Power consumption 310 W at 77°F (25°C)
320 W at 104
°F (40°C)
350 W at 131
°F (55°C)
4-Port 10-Gigabit Ethernet Line Card
Power consumption 310 W at 77°F (25°C)
320 W at 104
°F (40°C)
350 W at 131
°F (55°C)

Table of Contents

Other manuals for Cisco ASR 9006

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 9006 and is the answer not in the manual?

Cisco ASR 9006 Specifications

General IconGeneral
Chassis TypeModular
Rack Units10 RU
Slots6
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingFront-to-back airflow
Input Voltage100-240 VAC or -48 to -60 VDC
Supported ProtocolsIPv4, IPv6, MPLS, L2VPN, L3VPN
Interfaces10GE, 40GE, 100GE
Management InterfacesEthernet, Console, Auxiliary

Related product manuals