When using C1000-24T-4X-L and C1000-24P-4X-L switches with SFP-10G-ER or SFP-10G-ER-S SFP+
module, the thermal limitations are as follows:
Up to 5,000 ft (1524 m), the operating temperature should not exceed 113°F (45°C).
Up to 10,000 ft (3048 m), the operating temperature should not exceed 104°F (40°C).
When using C1000-24T-4G-L and C1000-24P-4G-L switches with GLC-BX-U or GLC-BX-D SFP module,
the thermal limitations are as follows:
Up to 5,000 ft (1524 m), the operating temperature should not exceed 113°F (45°C).
Up to 10,000 ft (3048 m), the operating temperature should not exceed 104°F (40°C).
Note
Power Requirements
Table 5: Power Requirements
Power Rating
(maximum
consumption)
CurrentFrequencyVoltage (auto
ranging)
Switch Model
0.08 kVA0.29A to 0.47A50 to 60 Hz110 to 220V AC inC1000-24T-4G-L
0.08 kVA0.29A to 0.47A50 to 60 Hz110 to 220V AC inC1000-24T-4X-L
0.45 kVA0.24A to 0.43A50 to 60 Hz110 to 220V AC inC1000-24P-4G-L
0.45 kVA0.24A to 0.43A50 to 60 Hz110 to 220V AC inC1000-24P-4X-L
0.8 kVA0.29A to 0.48A50 to 60 Hz110 to 220V AC inC1000-24FP-4G-L
0.8 kVA0.29A to 0.48A50 to 60 Hz110 to 220V AC inC1000-24FP-4X-L
0.06 kVA0.74A to 1.29A50 to 60 Hz110 to 220V AC inC1000-48T-4G-L
0.06 kVA0.74A to 1.29A50 to 60 Hz110 to 220V AC inC1000-48T-4X-L
0.5 kVA0.42A to 0.74A50 to 60 Hz110 to 220V AC inC1000-48P-4G-L
0.5 kVA0.42A to 0.74A50 to 60 Hz110 to 220V AC inC1000-48P-4X-L
0.95 kVA0.45A to 0.94A50 to 60 Hz110 to 220V AC inC1000-48FP-4G-L
0.95 kVA0.45A to 0.94A50 to 60 Hz110 to 220V AC inC1000-48FP-4X-L
Cisco Catalyst 1000 Series 24-Port and 48-Port Switch Hardware Installation Guide
43
Technical Specifications
Power Requirements

Table of Contents