Page #82 background imageLoading...
Page #82 background image
2-64
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PLATFORM_IPv6_UCAST Messages
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
Error Message PLATFORM_IPC-3-STACK_EVENT: [chars].
Note This message applies only to the Catalyst 3750-X and 3750-E switches.
Explanation There has been an IPC failure in the stack. [chars] describes the error message.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7.
PLATFORM_IPv6_UCAST Messages
Error Message PLATFORM_IPv6_UCAST-6-PREFIX: One or more, more specific prefixes
could not be programmed into TCAM and are being covered by a less specific prefix
Note This message applies only to the Catalyst 3750-X and 3750-E switches.
Explanation A more specific prefix could not be programmed into Ternary Content Addressable
Memory (TCAM) and is covered by a less specific prefix. This could be a temporary condition. The
output of the show platform ipv6 unicast retry route privileged EXEC command lists the failed
prefixes.
Recommended Action No action is required.
PLATFORM_PBR Messages
Error Message PLATFORM_PBR-2-NO_RMAP: Cannot create PBR data structures for
route-map [chars].
Explanation The PBR manager could not allocate the internal data structures for this route-map. A
likely cause is lack of available memory. [chars] is the route-map.
Recommended Action Simplify the configuration so that it requires less memory.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing

Related product manuals