2-24
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
DOT1X_SWITCH Messages
Error Message DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on
Interface [chars] AuditSessionID [chars]
Explanation Authentication was successful. The first [chars] is the client ID, the second [chars] is
the interface, and the third [chars] is the session ID.
Recommended Action No action is required
DOT1X_SWITCH Messages
Error Message DOT1X_SWITCH-5-ERR_ADDING_ADDRESS: Unable to add address [enet] on
[chars] AuditSessionID [chars]
Explanation The client MAC address could not be added to the MAC address table because the
hardware memory is full or because the address is a secure address on another port. [enet] is the
client MAC address, the first [chars] is the interface, and the second [chars] is the session ID.
Recommended Action If the hardware memory is full, remove some of the dynamic MAC addresses.
If the client address is on another port, remove it from that port.
Note This message applies to switches running the IP base image.
Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary
VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]
Explanation An attempt was made to assign a primary VLAN to an 802.1x port, which is not allowed.
[dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Use a different VLAN.
Note This message applies to switches running the IP base image.
Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid
secondary VLAN [dec] to PVLAN host 802.1x port [chars] AuditSessionID [chars]
Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host 802.1x
port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the port mode so that it is no longer a private VLAN host port, or use
a valid secondary VLAN.
Note This message applies to switches running the IP base image.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
Switching Capacity160 Gbps
Stacking Bandwidth64 Gbps
Max Stacking Units9
Layer SupportLayer 2 and Layer 3
Form FactorRack-mountable
DRAM256 MB
Flash Memory64 MB
ModelCisco Catalyst 3750-X Series
Ports24 or 48 10/100/1000 Ethernet ports
Uplink Interfaces4 SFP or 2 SFP+
FeaturesStackWise Plus, EnergyWise
ImageIP Base or IP Services
Operating Temperature0 to 40°C
Operating Humidity10 to 85% noncondensing

Related product manuals