EasyManua.ls Logo

Cisco Nexus 9300-FX

Cisco Nexus 9300-FX
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SpecificationCharacteristic
440 WMaximum output power
16 -8 AInput current
-36 to -72 VDCDC input voltage
-56 V@7.86 AOutput ratings
-36 VDC (minimum), -48 VDC (nominal), -72 VDC
(maximum)
Voltage range domestic
-36 VDC (minimum), -48 VDC (nominal), -72 VDC
(maximum)
Voltage range international
1841 BTUs per hour, 540 WTotal input BTU
2
1502 BTUs per hour, 440 WTotal output BTU
3
20 ABranch circuit protection
2
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on -36 VDC.
3
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on -36 VDC.
Power Cable Specifications
The following sections specify the power cable that you should order and use with AC power supplies.
Power Cable Specifications for AC Power Supplies
Cord Set DescriptionPower Cord Part NumberLocale
Power Cord Jumper, C13-C14
Connectors, 6.6 feet (2.0 m)
CAB-C13-C14-2M
Power cord, C13 to C14 (recessed
receptacle), 10 A, 9.8 feet (3 m)
CAB-C13-C14-AC
Cabinet jumper power cord, 250
VAC, 10 A, C14-C13 connectors,
2.3 feet (0.7 m)
CAB-C13-CBN
250 V, 10 A, 8.2 feet (2.5 m)CAB-250V-10A-ARArgentina
250 VAC, 10 A, 3112 plug, 8.2 feet
(2.5 m)
CAB-9K10A-AUAustralia
250 V, 10 A, 6.9 feet (2.1 m)CAB-250V-10A-BRBrazil