This switch runs with +1 redundancy mode, so that if one fan fails, the switch
can sustain operation. But if a 2nd fan fails, this switch is not designed to sustain
operation. Hence before waiting for major threshold temperature to be hit, the
switch will power down due to Powered-down due to fan policy trigger.
Note
Power supply modules (two—One for operations and one for redundancy [1+1]) with the following
choices:
500-W port-side intake AC power supply with burgundy coloring (NXA-PAC-500W-PI)
500-W port-side exhaust AC power supply with blue coloring (NXA-PAC-500W-PE)
1200-W port-side intake HVAC/HVDC dual-direction power supply with white coloring
(N9K-PUV-1200W)
930-W port-side intake DC power supply with burgundy coloring (NXA-PDC-930W-PI)
930-W port-side exhaust DC power supply with blue coloring (NXA-PDC-930W-PE)
All fan modules and power supplies must use the same airflow direction.
Note
The following figure shows the switch features on the port side of the chassis.
6 40/100-Gigabit QSFP28 ports248 100M/10GBASE-T ports1
BCN, STS, ENV LEDs3
To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver
Modules Compatibility Information document.