can connect your wrist strap. If you cannot find an ESD port, connect the wrist strap to an earth ground
(such as the grounding connection for the chassis).
Do not remove or insert a transceiver more often than necessary. Repeated removals and insertions can
shorten its useful life.
Keep the transceivers and fiber-optic cables clean and dust free to maintain high signal accuracy and to
prevent damage to the connectors. Attenuation (loss of light) increases with contamination and should
be kept below 0.35 dB.
Clean these parts before installing them to prevent dust from scratching the fiber-optic cable ends.
Clean the connectors regularly; the required frequency of cleaning depends upon the environment.
In addition, clean connectors if they are exposed to dust or accidentally touched. Both wet and dry
cleaning techniques can be effective; refer to your site's fiber-optic connection cleaning procedures.
Do not touch the ends of connectors. Touching the ends can leave fingerprints and cause other
contamination.
Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a
microscope to determine if damage has occurred.
Connecting Leaf Switches to APICs
You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf
switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual
interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect
the leaf switches to the APICs.
The VIC1225 module supports optical transceivers, optical cables, and switches with optical downlink
ports (such as: Cisco Nexus 93180LC-EX, 93180YC-EX, 93180YC-FX, 9332PQ, 9336C-FX2,
9348GC-FXP, 9372PX, 9372PX-E, and 9396PX switches).
The VIC1225T module supports copper connectors, copper cables, and switches with copper downlink
ports (such as: Cisco Nexus 93108TC-EX, 93108TC-FX, 93120TX, 93128TX, 9372TX, 9372TX-E, and
9396TX switches).
Before you begin
The APIC and leaf switches in the fabric must be fully installed in their racks and grounded.
Step 1 Connect an interface cable to one of the two ports on the virtual interface card (VIC) installed on the APIC. If the cable
is not already assembled to its transceivers, insert the transceiver into the VIC port and then connect the optical interface
cable to the transceiver.
For a VIC1225 optical module, use one of the following sets of transceivers and cables:
Cisco 10GBASE-LR transceivers (SFP-10G-LR) supporting a link length of up to 6.1 miles (10 km)
Cisco 10GBASE-SR transceivers (SFP-10G-SR) supporting the following link lengths:
Using 2000 MHz MMF (OM3) for up to 984 feet (300 m)
Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide
31
Connecting the Switch to the ACI Fabric
Connecting Leaf Switches to APICs